10.1 Early type master cylinder - check valve marked with arrow
2. Unscrew the connecting nuts and disconnect the hydraulic lines.
3. Disconnect the electrical wiring from the tank.
4. Remove the two nuts that secure the master cylinder to the booster, loosen the booster check valve clamp and lift the suspension up.
5. Remove the master cylinder from the booster posts and rod.
6. Installation is carried out in reverse order. Fill the reservoir with new fluid and bleed the system.
7. After bleeding the system, check the fluid level in the master cylinder reservoir.
Figure 9.9. Master cylinder hydraulic connections on later models