Removal and installation
1. Remove the central lower section of the instrument panel.
2. Disconnect the intake air volume control cable (manual air conditioner) or intake flap actuator connector (automatic air conditioner).
3. Remove the left front air duct at floor level.
4. Disconnect the fan motor wiring connector.
5. Remove 2 screws and 3 nuts, remove blower assembly.
Attention:
Check for leaks after installation.
Fastening nuts of the supercharger block:
: 4,31-5,73 N-m (0.44-0.59 kg m)
Blower unit fixing screws:
: 0.59-1.1V Nm (0.06-0.12 kg m)
Disassembly and assembly
Attention:
When installing the intake flap actuator, position it so that it fits snugly into the 1 flap link hole.
After installing the drives, set them to their original position (step 3 self-diagnosis, see below).