Ventilation switch cable
1. For power steering models, turn the mode switch to the DHF position (for right-hand drive models - to the VENT position).
2. Manually set the damper lever to the DEF position (VENT).
3. Pull the cable sheath in the direction of the arrows towards and (right-hand drive models - in the opposite direction) and secure it with a clip. Check the operation of the mode switch.
Draft of the crane of a heater
Disconnect the temperature control cable from the air mixer lever before adjusting the faucet rod. After completing the traction adjustment, attach and adjust the cable.
1. Push the mixer lever in the direction of the arrow.
2. Pull the faucet rod in the direction of the arrow so that the gap between the end of the rod and the lever is about 2 mm, and attach the rod to the faucet lever.
Temperature controller cable
1. For left hand drive models, turn the temperature control to the position corresponding to the maximum heating (for right-hand drive models - to the maximum cooling position).
2. Set the air mixer lever to the appropriate position.
3. Pull the cable sheath in the direction of the arrow (for right-hand drive models - in the opposite direction) and secure it with a clip. Check the operation of the temperature controller.