Tested contacts and resistance (at room temperature):
- Contacts 8 (+), 7 (-): not O or infinity Σ
- Contacts 8 (-), 7 (+): not O or infinity Σ
- Contacts 5 (+), 8 (-): not O or infinity Σ

- Contacts 5 (-), 8 (+): infinity Σ
- Contacts 7 (+), 5 (-): infinity Σ
- Contacts 7 (-), 5 (+): O or not infinity Σ
When measured with a digital tester, the resistance values will differ from those indicated.
Check if there is power supply from the distributor (rotor and distributor cap).
If the resistance values are different from the norm, replace the distributor.