Using a feeler gauge, measure the clearance between the connecting rod and the crank arm.
Standard: 0.200-0.350mm
Limit: 0.4mm
If the measured clearance is greater than normal, replace the connecting rod and re-measure the clearance. If the clearance exceeds the limit when remeasured, replace the crankshaft.