Amplifier check
Make connections according to the drawing. If the test lamp lights up when pins 1 or 6 are connected to the battery negative, the amplifier is OK.
Installation and adjustment
1. Turn the purifier on and off before installing the arms.
2. Raise the brushes and lower them onto the glass. Immediately before tightening the nuts, install the brushes at distances C and D from the upper edge of the decorative grille.
3. Apply washer fluid to the glass. Turn the purifier on and off.
4. Make sure the brushes stop at the same distances C and D.
- Distance C - 23-28 mm
- Distance D - 27-42 mm
Tighten the lever nuts to a torque of 21-26 Nm.
Before installing the levers, clean their axles with a metal brush. This will reduce the likelihood of loosening of the levers during operation.
Removal and installation of a windshield wiper drive
1. Remove 4 bolts securing the gearmotor (see fig.).
2. Disconnect the motor reducer from the rod.
3. Remove the cleaner mechanism. Be careful not to tear the protective cover of the ball joint.
Lubricate the ball joint with multipurpose grease before installation.
5. Installation is carried out in the reverse order.