2. Set the plate to the "N" position.

3. Remove the three bolts and PNP sensor.
4. Installation is carried out in reverse order. Please note the following points.
5. Align the hole in the PNP sensor with the hole in the plate when the AT is in "N" mode, and insert the pin into these holes.
6. After installation, check the operation of the sensor and adjust the selector cable (see section Adjusting the selector cable).