Note: Electric motors are used only on models with automatic c/v (see illustration Assembly of the K/V block of models with manual control).

1. To remove the damper electric motor air supply remove the glove compartment cover and unscrew the three screws.
2. To remove the electric motors of the dampers air distribution and air mixing modes remove the glove box instrument panel pillar cover and remove the three screws.

Air distribution flap electric motor mounting screws

Air Mixing Damper Motor Fastening Screws
Note: After removing these motors, reset them to their original position (see section Automatic CV self-diagnosis).